MultiPalmsens4

  • 4 to 10 channels available in different configurations
  • FRA / EIS: 10 μHz up to 1 MHz
  • 9 current ranges: 100 pA to 10 mA
  • potential range: ±5 V or ±10 V

 

Description:

The MultiPalmSens4 is a multi-channel potentiostat, galvanostat and impedeance analyzer. The MultiTrace software allows for you to use each channel individually or simultaneously or running a sequence of automated tasks on each channel. Each channel provides an additional auxiliary port for controlling peripherals or monitoring temperature or other analog signals.

Techniques:

Voltammetric Techniques:

  • Linear Sweep Voltammetry (LSV)
  • Cyclic Voltammetry (CV)
  • Fast Cyclic Voltammetry (FCV)
  • AC Voltammetry (ACV)

Pulsed Techniques:

  • Differential Pulse Voltammetry (DPV)
  • Square Wave Voltammetry (SWV)
  • Normal Pulse Voltammetry (NPV)

Amperometric Techniques:

  • Chronoamperometry (CA)
  • Zero Resistance Amperometry (ZRA)
  • Chronocoulometry (CC)
  • MultiStep Amperometry (MA)
  • Fast Amperometry (FAM)
  • Pulsed Amperometric Detection (PAD)
  • Multiple-Pulse Amperometric Detection (MPAD)

Galvanostatic Techniques:

  • Linear Sweep Potentiometry (LSP)
  • Chronopotentiometry (CP)
  • MultiStep Potentiometry (MP)
  • Open Circuit Potentiometry (OCP)
  • Stripping Chronopotentiometry (SCP or PSA)

Other Techniques:

  • Mixed Mode (MM)

Potentiostatic/Galvanostatic Impedance Spectroscopy (EIS/GEIS):

  • Potential scan or current scan
  • Fixed potential or fixed current
  • Time scan

Specifications:

General
Dc-potential range ± 10 V (or ± 5 V) *
Compliance voltage ± 10 V
Maximum current ± 30 mA (typical)
Max. acquisition rate 150,000 data points/s
Potentiostat (controlled potential mode)
Applied dc-potential resolution 76.3 µV
Applied potential accuracy ≤ 0.1% ±1 mV offset
Current ranges 100 pA to 10 mA (9 ranges)
Current accuracy ≤ 0.1 % (at Full Scale Range)
Measured current resolution 0.005 % of current range (5 fA on 100 pA range)
0.0025% of 10 mA range
Galvanostat (controlled current mode)
Current Ranges 1nA to 10 mA (8 ranges)
Applied dc-current range ±6 times current range
Applied dc-current resolution 0.0076% of applied current range (<10 mA)
0.0038% of 10mA range]
Measured dc potential resolution 78.13 uV at ±10V
7.813 uV at ±1V
0.7813 uV at ±0.1V
Measured dc potential accuracy ≤ 0.05% or ±1mV (for |E|< ±9V
≤ 0.2% (for |E|≥ ±9V
FRA / EIS (impedance measurements)
Frequency range 10 μHz to 1 MHz (or 10 μHz to 100 kHz) *
Ac-amplitude range 1 mV to 0.25 V rms, or 0.6 V p-p
GEIS (galvanostatic impedance measurements)
Frequency range 10 μHz to 100 kHz (or 10 μHz to 100 kHz)
Ac-amplitude range 0.001 x CR to 0.4 x CR (<10 mA)
0.001 x CR to 0.2 x CR (10 mA)
Electrometer
Electrometer amplifier input > 1 TΩ // 10 pF
Bandwidth 1 MHz
Auxiliary port (D-Sub 15)
Analog input ±10 V, 18 bit
Analog output 0-10 V, 12 bit (1 kOhm output impedance)
4 digital outputs 0-5 V
1 digital input 0-5 V
I-out and E-out raw output of current and potential
E-out ±10 V (1 kOhm output impedance)
i-out ±6 V (1 kOhm output impedance)
Power 5 V output (max. 150 mA)
Instrument
Housing 15 x 25 x 25 cm3
Weight +/- 4 kg
Temperature range 0 ºC to + 50 ºC
Power supply external 12 V AC/DC adapter
Communication USB
Internal storage space 8 GB per channel or +/- 800000 measurements incl. method info (assuming 200 data points per measurement)
Potentiostat (controlled potential mode)
Applied dc-potential resolution 76.3 µV
Applied potential accuracy ≤ 0.1% ±1 mV offset
Current ranges 100 pA to 10 mA (9 ranges)
Current accuracy ≤ 0.1 % (at Full Scale Range)
Measured current resolution 0.005 % of current range (5 fA on 100 pA range) 0.0025% of 10 mA range

Software:

MultiTrace for Windows: 

MultiTrace is the software used to control the multi-channel instruments. It looks similar to the PSTrace and comes included with the instrument on  USB drive. You have the ability to control all the channels at once or individually.