Specialists in Electrochemistry & Materials, Energy & Power

Battery Cyclers

We offer a range of battery cyclers and formation systems together with ancillary products and materials. Cyclers range from single channel to high channel counts, uA up to 1,000’s of kiloamps.

Note, that this page is focused on cyclers and higher power potentiostats which are often used for cycling and often with impedance. Many of our broader range of potentiostats are also used in battery labs and materials research labs and can be found on our potentiostats page here.

Battery Cyclers

580 & 585 Battery Cyclers

580 (1A) resting on 585 (5A) battery cycler.

8-channel, 1A and 5A battery cyclers from Scribner.  Each includes High Frequency Resistance capability for ac measurement of battery internal resistance.

Cell Test System (CTS)

BaSyTec CTS Lab System with 32 Channels

Cell testing to 6V and 5A (20A in parallel operation) on each of 32 independent test channels (each with temperature input). 200nA precision for low current measurements.

HPS-HR Test Systems

hps-hr-1024x1024

Voltage and currents can be adapted to your requirements in this modular system with up to 2400A and 70 V (max 6 KW ) in this modular, 4-channel design.

IviCycle

IviCycle range of 32 channel potentiostat and battery cycler. Milliamps to Amps. Modular.

32 channel battery test system with impedance / EIS. Combines cycler and potentiostat capability and software. Modular design with selectable modules from 30mA to 3A. Systems can be combined to 256 channels. Each channel is an independently programmable potentiostat + cycler + ZRA.

LPS-HR Test Systems

lps-1024x1024

With 24Bit resolution and current ranges configurable between 100µA to 60A per channel (parallelable to 4x) and voltage to 70V, this system replaces BaSyTec’s MDS, GSM and LPS models.

MRS-HR Cell Test System

MRS-HR Module test system

Designed for very high currents, this system delivers up to 2,400A in a highly energy efficient design.

MRS-HR Module Test System

mrs-module-tester-1024x1024

Voltages to 70 V, currents to 540A delivered by a modern switched mode design ensures high energy efficiency with reduced cooling required to run this system.

NanoCycler – Battery Cycler

Nanocycler with accessories and extenders

A compact, easy-to-use high density and multichannel 200mA battery cycler designed to test standard 2032 and 2025 coin cells (also lower power pouch cells) in the laboratory environment.

OctoStat Series

Ivium Octostat5000 from OctoStat range
  • 8-channel Potentiostat/Galvanostat/ZRA
  • Stackable to128 channels
  • Independent FRA/EIS per channel
  • Runs without pc controller
  • No data loss on pc disconnect

OrigaFlex Multichannel Potentiostat System

Origaflex example configuration

Origalys’s Origaflex is a modular potentiostat system with a range of potentiostat modules up to ±10A and with compliance voltage of ±20V (±15V Applied). Applications include electrochemistry and battery research.

RPS Battery Pack Test System

rps-600-1024x1024

The RPS-HR Battery Pack tester is for voltages up to 1500V and currents up to 1000A and a maximum power of 500kW. A Battery safety (BSD) is integrated in the system and many additional options are possible.

XCTS Mk2 Series

basytec-xcts-1024x1024

Cell testing to 6V and models to 80A (800A in the optional parallel mode) and includes automatic dynamic current range switching.